The Two Numbers That Matter
Flow rate is gallons per minute (GPM), and temperature rise is how many degrees the unit must add to incoming water. A unit that can deliver 5 GPM at a 70 degree rise is a very different machine from one that delivers 5 GPM at a 40 degree rise.
Start by listing the fixtures that could run at the same time. That sets the flow you need. Then decide the temperature you want at the tap and subtract the incoming water temperature to get the rise.
Typical Flow Rates by Fixture
These are common ranges. Your fixtures may differ, so check labels.
| Fixture | Typical flow (GPM) |
|---|---|
| Bathroom sink | 0.5 to 1.5 |
| Kitchen sink | 1.5 to 2.5 |
| Shower | 1.5 to 2.5 |
| Dishwasher | 1 to 2 |
| Washing machine | 1.5 to 3 |
Add the fixtures that run together on a busy morning. That total is your design flow.
Want a Plumber to Look at It?
Call the 24/7 line, any hour.
A Simple Sizing Method
Count simultaneous fixtures
Think about the worst-case morning, such as two showers and a dishwasher.
Add their flow
Use the table above to total gallons per minute.
Find the temperature rise
Subtract the coldest incoming water from your target temperature.
Check the unit rating
The manufacturer lists GPM at several rises. Pick one that meets your flow at your rise.
Lebanon Note: Plan for the Coldest Month
Incoming water in the Willamette Valley is colder in winter than summer, and the temperature rise grows accordingly. A unit sized for a mild day may fall short in a January freeze, such as the cold snap that hit the southern valley in 2017. Size for the cold months and the unit will cope in the warm ones.
We do not publish a fixed incoming temperature because it varies by season and by how your lines run. Measure at your tap, or ask us to check during a visit.
Manufacturer rating tables are the source for flow at each temperature rise, and the Uniform Plumbing Code (UPC) sets the gas and venting requirements that limit unit size.
When Sizing Points to One Unit or Two
One unit is likely enough when
- Only one or two fixtures run together.
- Hot water use is steady.
- Incoming water is not extremely cold.
Consider two units or a tank when
- Three or more bathrooms run together.
- A large soaking tub is used often.
- Gas line or venting limits unit size.
Gas or Electric Changes the Limits
Gas units tend to reach higher flow at larger temperature rises than electric ones, but they need venting and a properly sized gas line. Electric units need heavy circuits instead. Either choice shapes what you can fit.
See our pages on installation and replacement for planning. We cover Brownsville and Scio as well.
A Worked Example
Suppose a family of four wants one shower and a dishwasher to run together. The shower uses about 2 GPM and the dishwasher about 1.5 GPM, so design flow is 3.5 GPM. If incoming water in January is 45 degrees and the shower needs to be 105 degrees at the tap, the temperature rise is about 60 degrees.
The unit must deliver at least 3.5 GPM at a 60 degree rise. Many units list their flow at different rises, so find the row that matches. A model that gives 5 GPM at a 40 degree rise might only give 3 GPM at 60, and that would fall short. These numbers are an illustration, not a promise, so check the actual ratings.
Mistakes That Cause an Undersized Unit
- Sizing for average use, not peak use. The busiest morning sets the load.
- Using summer water temperature. Winter inlet water is colder.
- Ignoring low-flow fixtures. They reduce demand, which helps, but not everywhere.
- Forgetting the dishwasher and laundry. They run while someone showers.
When a Second Unit or a Tank Makes More Sense
Large households or homes with distant bathrooms may do better with two smaller units or a tank. Two units can serve different parts of the house and reduce wait time for hot water at far fixtures.
A planned installation starts with a site visit where we count fixtures, measure pipe runs and check gas or electric capacity. That visit usually answers the question better than any formula.
Where the Numbers Come From
Flow rates on fixtures are printed on the product or in its manual, and many modern fixtures are labeled with a maximum GPM. Incoming water temperature can be measured directly with a thermometer at a cold tap after a minute of running. Manufacturers publish rating tables that show flow at several temperature rises.
Using real numbers beats guessing. If you plan a replacement soon, gather them before you call so the visit can focus on the right model.
Tankless Water Heater Sizing: Local Questions
Run the cold tap for a minute and measure with a thermometer, or ask a plumber to check on site.
No. An oversized unit costs more and may need a larger gas line or panel. Match the unit to your design flow.
Water comes out lukewarm when several fixtures run together.
Sometimes. Space, venting and gas or electrical capacity decide.
Colder incoming water means a bigger temperature rise, which lowers the flow a unit can deliver.